An Enclosure is a cabinet generally fitted with doors and side panels. Enclosures may contain baffles, fans, and other features. Then can be mounted inside a Rack or directly fitted on the wall.
Name | Type | Mandatory? |
---|---|---|
Name | Alphanumeric string | Yes |
Organization | Foreign key to a(n) Organization | Yes |
Status | Possible values: implementation, obsolete, production, stock | No |
Business criticity | Possible values: high, low, medium | No |
Location | Foreign key to a(n) Location | No |
Rack | Foreign key to a(n) Rack | Yes |
Brand | Foreign key to a(n) Brand | No |
Model | Foreign key to a(n) Model | No |
NB U | Numeric value (could be negative) | No |
Serial number | Alphanumeric string | No |
Asset number | Alphanumeric string | No |
Move to production date | Date (year-month-day) | No |
Purchase date | Date (year-month-day) | No |
End of warranty | Date (year-month-day) | No |
Description | Multiline character string | No |
Tab | Description |
---|---|
Contacts | All the contracts for this configuration item |
Documents | All the documents linked to this configuration item |
Tickets | All the tickets for this configuration item |
Devices | All the devices in this enclosure |
Provider contracts | All the provider contracts for this configuration item |
Click on the “Overview” menu:
And click on “Create a new Enclosure” in the dashboard:
To display the following form:
A PDU (Power Distribution Unit) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center.
Name | Type | Mandatory? |
---|---|---|
Name | Alphanumeric string | Yes |
Organization | Foreign key to a(n) Organization | Yes |
Status | Possible values: implementation, obsolete, production, stock | No |
Business criticity | Possible values: high, low, medium | No |
Location | Foreign key to a(n) Location | No |
Rack | Foreign key to a(n) Rack | Yes |
Power start | Foreign key to a(n) Power Connection | No |
Brand | Foreign key to a(n) Brand | No |
Model | Foreign key to a(n) Model | No |
Serial number | Alphanumeric string | No |
Asset number | Alphanumeric string | No |
Move to production date | Date (year-month-day) | No |
Purchase date | Date (year-month-day) | No |
End of warranty | Date (year-month-day) | No |
Description | Multiline character string | No |
Tab | Description |
---|---|
Contacts | All the contracts for this configuration item |
Documents | All the documents linked to this configuration item |
Tickets | All the tickets for this configuration item |
Provider contracts | All the provider contracts for this configuration item |
Click on the “Overview” menu:
And click on “Create a new Power Connection” in the dashboard:
Then select “PDU” in the form below:
And click “Apply” to display the PDU creation form:
A Power Source is used to document in iTop any kind of power source (main power inlet, breaker…) that is not a PDU.
Name | Type | Mandatory? |
---|---|---|
Name | Alphanumeric string | Yes |
Organization | Foreign key to a(n) Organization | Yes |
Status | Possible values: implementation, obsolete, production, stock | No |
Business criticity | Possible values: high, low, medium | No |
Location | Foreign key to a(n) Location | No |
Brand | Foreign key to a(n) Brand | No |
Model | Foreign key to a(n) Model | No |
Serial number | Alphanumeric string | No |
Asset number | Alphanumeric string | No |
Move to production date | Date (year-month-day) | No |
Purchase date | Date (year-month-day) | No |
End of warranty | Date (year-month-day) | No |
Description | Multiline character string | No |
Tab | Description |
---|---|
PDUs | All the PDUs using this power source |
Contacts | All the contracts for this configuration item |
Documents | All the documents linked to this configuration item |
Tickets | All the tickets for this configuration item |
Provider contracts | All the provider contracts for this configuration item |
Click on the “Overview” menu:
And click on “Create a new Power Connection” in the dashboard:
Then select “PowerSource” in the form below:
And click “Apply” to display the Power Source creation form:
A computer Rack is a metal frame used to hold various hardware devices such as servers, hard disk drives, other electronic equipment. The available space inside a Rack is mesured the unit “U” (One U corresponds to 1.75 inches of space between each hole on the metal strips on the sides for screwing the devices in place)
Name | Type | Mandatory? |
---|---|---|
Name | Alphanumeric string | Yes |
Organization | Foreign key to a(n) Organization | Yes |
Status | Possible values: implementation, obsolete, production, stock | No |
Business criticity | Possible values: high, low, medium | No |
Location | Foreign key to a(n) Location | No |
Brand | Foreign key to a(n) Brand | No |
Model | Foreign key to a(n) Model | No |
NB U | Numeric value (could be negative) | No |
Serial number | Alphanumeric string | No |
Asset number | Alphanumeric string | No |
Move to production date | Date (year-month-day) | No |
Purchase date | Date (year-month-day) | No |
End of warranty | Date (year-month-day) | No |
Description | Multiline character string | No |
Tab | Description |
---|---|
Contacts | All the contracts for this configuration item |
Documents | All the documents linked to this configuration item |
Tickets | All the tickets for this configuration item |
Enclosures | All the enclosures in this rack |
Devices | All the physical devices racked into this rack |